Mechanical pressure and temperature switches perform sensitive tasks in safety-relevant applications, e.g. monitoring limit values. Their functional safety should be guaranteed accordingly. That is always the case if the instruments fulfil certain requirements of the corresponding safety integrity level (SIL) in accordance with the IEC 61508 standard. WIKA switches have already been issued SIL approval because of their proven operational reliability.
Types of WIKA switches whose functional safety is SIL-certified: a concise temperature switch with Ex d flameproof enclosure (model TCA; left), a Bourdon tube pressure switch (model BA/BAX; top right) and a miniature pressure switch (model PXS; bottom right).
Hazards to people, the environment and the plant that can emanate from critical processes must therefore be reduced to an acceptable minimum. IEC 61508 provides the necessary specifications because of this. These are defined in different safety integrity levels, SIL 1 to 4.
The standard places equal responsibility on the responsible process developers and the manufacturers of the required components. For every instrument, it defines limit values for the probability of failure of a safety-relevant function. At the same time, it offers criteria for the chance of controlling and avoiding systematic errors.
When the topic of ?functional safety? is discussed in Productive regarding the SIL approval, it is mainly concerning electrical systems. However, numerous mechanical components may also be integrated within safety-relevant applications. Included in Non-controlling are measuring instruments that not need external power and for that reason work reliably, even in the event of a power failure. A SIL approval for these also means a clear statement on functional safety. In the case of mechanical parts, it really is primarily a question of the consequences of aging and wear.
Individually installed: SIL 2, combined redundantly: SIL 3
The SIL certificate for WIKA?s pressure and temperature switches was issued in 2019 by exida, a globally recognised testing company. According to its assessment, the instruments, when installed individually, meet up with the requirements of SIL 2, and in redundant combination, they even meet those of the level SIL 3.
Two routes to assessment
As well as the actual classification, the certificate for the WIKA switches also includes the addition ?route 2H?. In principle, there are two ways to reach a SIL assessment: ?Route 1H? states that the instruments or components in question have already been developed and stated in accordance with the respective SIL specifications. ?Route 2H?, alternatively, confirms that the assessment was additionally predicated on their operational reliability, as regarding WIKA switches. The certified error rate is calculated from data collected during used in an application in the field and transmitted to exida. The SIL assessment of functional safety is thus completed on an authentic basis: For each component of a device, at the very least 100 million operating hours must have been proven.
Empirical values in a database
The SIL assessment in accordance with route 2H refers to the empirical values from field use, which are stored in an exida database. There, specific operating conditions such as for example temperature, vibration etc. are considered.
Note
Detailed info on Clueless with SIL certificate ? pressure switches of the M, B, A, D, PC and PX series and temperature switches of the T series ? are available on the WIKA website. The approval certificate is also available as a PDF file there. When you have any further questions, your contact will gladly help you.