In many places from chemistry laboratories to industrial amenities, so as to guarantee the protection of life and property against a potential hearth hazard, extinguishing techniques are used along with detection and alarm methods. It can also be extremely necessary that the extinguishing methods put in may be triggered by the fire extinguishing management panel, so as to remove a possible fireplace with early intervention.
In order to meet these needs, and with 35 years of sectoral data and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel working according to the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing process to be began manually and remotely; and
to make sure that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount technology and are aimed at making the automation of the extinguishing system and fireplace and gas detection system excellent.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times considering the needs of the set up. In cases that require the combination of the extinguishing system with the intelligent addressable fireplace detection system, it offers solutions through the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an important role in controlling the continuity of the cable connection between the loop and the extinguishing system. เกจวัดแรงดันน้ำ10บาร์ to detect a possible open or brief circuit within the wiring between the contact monitoring modules and the peripheral techniques can cause disruption of the triggering, with doubtlessly critical consequences. For this purpose, when choosing monitoring modules, it should be taken into consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable hearth detection and alarm management panels are continuously communicating with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions corresponding to open circuits and short circuits that will occur in the system. Many duties could be performed within the fireplace extinguishing installation, such as the management and monitoring of all valves that can interrupt the circulate of water, water circulate alarm switches, pressure switch, and electrical or diesel fireplace pumps.
By adding two contact monitoring modules to two separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to control errors and the opposite to manage the hearth state of affairs, monitoring and management of the extinguishing system through an clever addressable hearth detection and alarm system can be performed effectively.
For more info, go to www.mavili.com.tr/en
Share